A purchase order that only says hot dip galvanized leaves the most important number open. Coating thickness decides service life, and it is the first thing an inspector checks. Here is what to write down.

The standard in one table

China GB/T 13912-2020 sets coating thickness by part thickness. For flat bar and round bar of 6 mm and above, which covers most structural and grounding work, the requirement is average 85 microns and local minimum 70 microns.

Part thicknessAverageLocal minimum
6 mm and above85 microns70 microns
3 to 6 mm70 microns55 microns
1.5 to 3 mm55 microns45 microns
below 1.5 mm45 microns35 microns

Coating and mass

Zinc density is 7.14 g per cubic centimetre, so one micron of coating equals about 7.14 g per square metre on one face. A 85 micron coating is roughly 600 g per square metre single face. Certificates sometimes state coating mass instead of thickness, and the two can be converted with this factor.

Process decides the ceiling

Air knife lines produce a very even 60 to 85 microns. Hanging galvanizing, with 3 to 5 minutes in a 445 to 455 C kettle, reaches 85 to 120 microns and is the right choice for buried, coastal and chemical plant use. Continuous strip galvanizing, common for thin sheet, is only 20 to 40 microns per face and is not a substitute for structural parts.

How to check on arrival

Use a magnetic gauge, take three to five readings on flat areas, keep away from edges and weld seams. For a disputed batch, the weighing method dissolves the coating and weighs the difference. Both are described in GB/T 4956 and GB/T 4955.

What to put in the contract

Write material grade, section size and tolerance, coating average and local minimum, surface acceptance (no skip coating, no zinc lumps affecting assembly), and the inspection method. That removes almost all argument at delivery.